SKYLINE D1.5m Fire Testing Equipment 30-50KPa Vertical Furnace

SKYLINE D1.5m Fire Testing Equipment 30-50KPa Vertical Furnace

MOQ: 1 unit
Price: negotiated
Standard Packaging: Plywood case
Delivery Period: 35 working days
Payment Method: T/T
Supply Capacity: 1 unit/ month
Detail Information
Place of Origin
CHINA
Brand Name
SKYLINE
Certification
Calibration Certificate
Model Number
SL-1634
SKYLINE:
Vertical Furnace
Furnace Dimension:
H4.0×W4.0×D1.5m
Working Temperatur:
≤1200℃
Fuel Calorific Value:
25000 Kcal/m3
Fuel Preasur:
30-50KPa;
Furnace Air Volume:
≈ 4000Nm3/h
Highlight:

50KPa Fire Testing Equipment

,

D1.5m Fire Testing Equipment

,

50KPa vertical flammability tester

Product Description

EN 1363-1 Vertical Furnace

 

 

Standard reference

The vertical furnace reference with:

  • ISO834-1 Fire resistance tests – elements of building construction Part 1: General requirements.
  • EN 1363-1 Fire resistance tests – Part 1: General requirements
  • EN 1363-2 Fire resistance tests – Part 2: Alternative and additional procedures
  • BS 476-20Fire tests on building materials and structures – Part 20: Method for determination of the fire resistance of elements of construction (General Principles)
  • BS 476-24 Fire resistance test on building materials and structures – Parts 24: Method for determination of the fire resistance of ventilation ducts

Technical parameters

Furnace type:Vertical furnace—H4.0×W4.0×D1.5m

Furnace type: vertical furnace;

samples:Vertical parts such as fire doors, fire windows, fire shutter doors, etc.;

Testing chameb dimension: H4.0m*W4.0m*D1.5m;

Furnace Door quantity: 1 sample rail car + 2 sample frames;Design temperature: ≤1300℃;

Working temperature: ≤1200℃;

Fuel tyep: LPG;

Fuel calorific value: 25000 Kcal/m3;

Fuel preasure: 30-50KPa;

Exhaust smoke temperaure: ≤300℃(air cooled),Into the environmental protection system flue gas temperature;

Exhaust smoke method:The temperature of the flue gas in the furnace drops below 300℃, and then it is sent to the general manager through the exhaust fan

The exhaust pipe is transported to the environmental protection system.

Furnace air volume: ≈ 4000Nm3/h

Furnace wall temp.rais : ≤Room temperature +50°C (non-burner and the area around the observation window);

Insulation material: Refractory brick;

quantity of burners: burners-12 sets; the power of a single burner ≤300kw;

 

What is a test fire and why is it important?
What Is Fire Testing? Fire testing intends to understand the influence of a direct flame on a material or product. Companies may analyze the effect on wiring or cable, building materials or furnishings.

 

Sitemap |  Privacy Policy | China Good Quality Lab Testing Equipment Supplier. Copyright © 2024-2025 SKYLINE INSTRUMENTS CO.,LTD . All Rights Reserved.