Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
-
Assembly
-
Capabilities
- About Us
- contact
- Quote
EN ISO 20344 Shoe Insulation Testing Machine CE
| SKYLINE: | Shoe Insulation Testing Machine |
|---|---|
| Sand Volume: | 5000 ± 250cm3 |
| Sand Size: | 0.3~1.0mm |
| Standards: | ISO-20344 |
| Heating Power: | 2500 ± 250W Or More |
Cable Fire Resistance Test Equipment UL 2556 / UL 1581
| SKYLINE: | VW-1 Flammability Tester |
|---|---|
| Standards: | UL2556-2013 |
| Burning Time Setting: | 0~999S |
| Air Source: | Methane, Air |
| Test Box Size: | 2m(W)×1.2m(D)×1.8m(H) |
ASTM D2843 Smoke Density Tester For Building Materials
| SKYLINE: | Smoke Density Flammability Tester |
|---|---|
| Standards: | ASTM D 2843,DIN 4102 |
| Application: | Smoke Density Test |
| Gas: | 95% Propane Gas |
| Controller: | Touch Screen |
EN ISO 11925 Building Materials Ignitability Flammability Tester
| Building Material: | Flammability Testing Equipment Ignitability Tester |
|---|---|
| Standards: | EN11925-2 |
| Application: | Building Material |
| Box Size: | 835 X Depth 400 X High 815mm |
| Material: | 1.5mm Stainless Steel |
Closed Cup Pensky Martens Flash Point Tester ASTM D93
| SKYLINE: | Closed Cup Flash Point Tester |
|---|---|
| Standard: | ASTM D93 |
| Oil Cup Inner Diameter: | 50.7mm~50.8mm. |
| Oil Cup Depth: | 55.7mm~56.0mm |
| The Scribed Line Depth Of Capacity Of Testing Oil: | 33.9mm~34.3mm. |
high Accuracy NBS Smoke Density Chamber Test Equipment For Wire And Cable Products
| SKYLINE: | NBS Smoke Density Chamber |
|---|---|
| Diameter Of Light Beam: | Approx. 38mm |
| Temperature Of Sample: | 23±2°C |
| Relative Humidity: | 50±5℅ |
| Accuracy Of Photometer: | ±3% |
EN54-7 / EN14604 Smoke Fire Detector Test Tunnel
| SKYLINE: | EN54-7/14604 Smoke Fire Detector Test Tunnel |
|---|---|
| Standards: | EN54-7"point-type Smoke Detectors": EN14604 |
| The Test Area: | 425mm*425mm*1100mm |
| Airflow Speed: | 0.8m/s±0.1m/s, 0.2m/s±0.04m/s, 1.0m/s±0.2m/s |
| Optical Measurement Length: | Not More Than 1.1m |
ASTM D445 Kinematic Viscosity Meter Lubricating Oil Analysis Testing Equipment
| Standard: | ASTM D445 |
|---|---|
| Heating Power: | Less Than 1500W |
| The Number Of Holes Of Liquid Bath: | 4 Holes |
| Temperature Control Range: | Room Temperature -100 ° C |
| Ambient Temperature: | 0℃~+40℃ |
IEC 61032 75N Test Probe 11 Rigid Finger Probe Anti Shock Test Finger Probe 11
| Materials: | Nylon Stainless Steel |
|---|---|
| Nodular Finger Length: | 80mm |
| Nodular Finger Diameter: | 12mm |
| Dam-board Diameter: | 50mm |
| Dam-board Thickness: | 5mm |
UL 1685 / UL 2556 Standard Vertical Flame And Smoke Release Test Chamber For Fibre Optic Cables
| UL: | UL Cable Vertical-Tray Flaming Test Room(UL1685) |
|---|---|
| Inner Size: | Height 3353mm, Length 2438mm, Width 2438mm; |
| Propane Flow Meter: | 230 Mm³/s |
| Air Flow Meter: | 1330 Mm³/s |
| Standard Luminous Flux: | 2000lm-3000lm |