ASTM D1709 AB Method Plastic Film Dart Impact Testing Machine Falling Dart Impact Tester

ASTM D1709 AB Method Plastic Film Dart Impact Testing Machine Falling Dart Impact Tester

MOQ: 1 Unit
Price: negotiated
Standard Packaging: plywood case
Payment Method: L/C, D/P, T/T, Western Union, MoneyGram
Supply Capacity: 10 unit / month
Detail Information
Place of Origin
CHINA
Brand Name
SKYLINE
Certification
CE , Calibration Certificate
Model Number
SL-FD33
Measuring Range:
50~2000g/300~2000g
Measuring Accuracy:
0.1g (0.1J)
Test Condition:
23℃,50%RH (standard)
Sample Clamping:
Pneumatic
Sample Size:
>150mm×150mm
5g/increment Dart Diameter:
38±1mm/50±1mm
Impact Height:
1500mm/660mm
Power:
AC 220V 50Hz
Highlight:

ASTM D1709 Impact Tester

,

Plastic Film Impact Tester

,

Dart Impact Testing Machine

Product Description

ASTM D1709 AB method Plastic film Drop Dart Tester

 

 

Introductions

Falling darts impact tester apply to plastic film or chip which thickness less than 1mm impact by fall darts in a given great freedom to fall, test the impact quality and energy were when 50% plastic film or chip was damaged.

 

Standards

GB/T 9639.1-2008, ASTM D1709, IS0 7765-1-1988, JIS K7124-1 Configuration of the host computer, A method (B method optional) dart head, foot switch

 

Working Principle

When trial is beginning,firstly choice test methods, estimates that an initial quality and Δ m value, and than testing, if the first sample damaged, with Jordan farmar Δ m reduce falling body quality; If the first don't break, should be in Jordan farmar Δ m increase fall body quality, based on to test. In a word, use farmar to reduce or increase the quality of fall, depends on the a sample for damage or breakage. After test 20 samples, to calculate the damage total N, if N = 10, the experiment is complete; If N<10, supplement the sample, continue to test until N=10; If N>10, supplement the sample, continue to test until no damage is equal to the total number is 10, finally automatic calculation the shock results by the system.

 

Features

1.7 inch high brightness LCD touch screen is convenient for parameter setting and test operation.

2.Support two test methods: A method and B method.

3. Test results are displayed in various units

4. Electromagnetic dart drop, fixed position automatic release, specimen pneumatic centralised.

5. Computer software (optional)

6. Manual and foot-operated start-up modes.

7. Built-in observation lamp for easy judgement of specimen status.

8. Micro-printer for easy printing of test results

 

 

Technical parameter

Method A method(Optional) B method(Optional)
Measuring range 50~2000g 300~2000g
Measuring accuracy 0.1g (0.1J)
Test condition 23℃,50%RH (standard)
Sample clamping pneumatic
Sample size >150mm×150mm
5g/increment dart diameter 38±1mm 50±1mm
Impact height 1500mm/660mm
Power AC 220V 50Hz
Air supply 0.6 MPa (air source user-provided) air source interface 8mm
Dimension 500(L)*450(W)*1200mm(H) 500(L)*450(W)*2200mm(H)

 