products
PRODUCTS DETAILS
Home > Products >
27kg/Cm2 Lab Testing Equipment LPG Gas Regulating Station

27kg/Cm2 Lab Testing Equipment LPG Gas Regulating Station

MOQ: 1 unit
Price: negoitable
Standard Packaging: Plywood case
Delivery Period: 15 working days
Payment Method: T/T, Western Union, MoneyGram
Supply Capacity: 1 unit
Detail Information
Place of Origin
CHINA
Brand Name
SKYLINE
Certification
Calibration certificate
SKYLINE:
LPG Gas Regulating Station
Equipment Design Flow:
300Kg/h
Design Pressure:
2.7MPa (27kg/cm2);
Hydraulic Test Pressure:
3.3MPa (33kg/cm2);
Airtight Test Pressure:
2.7MPa (27kg/cm2);
Working Temperature:
50℃-80℃.
Highlight:

27kg/cm2 Lab Testing Equipment

,

LPG Lab Testing Equipment

,

27kg/cm2 gas regulating station

Product Description

LPG Gas Regulating Station

 

The Function of LPG Gas Regulating Station:

Pressure regulation, heat exchange and gasification functions for gas;

Over pressure relief function;

On-site display function of pressure at each point;

 

Technical Parameter

Equipment design flow: 300Kg/h

Structure: 12 bottle groups,

Pressure regulation method: one-stage pressure regulation,;

Heat exchange method: primary heat exchange, air-heated air convection heat exchange

Equipment inlet pressure and pipe diameter: 1.6 MPa DN25

Equipment outlet pressure and pipe diameter: 0.05MPa DN80

Design pressure: 2.7MPa (27kg/cm2);

Hydraulic test pressure: 3.3MPa (33kg/cm2);

Airtight test pressure: 2.7MPa (27kg/cm2);

Opening pressure of safety valve: 1.76MPa (17.6kg/cm2); 5

The explosion-proof grade of the vaporizer is: DⅡBt4;

Working temperature: 50℃-80℃.

 

Features

HD Liquefied Gas Vaporizers are advanced in technology, safe and reliable, with gasification energy ranging from 50KG to 500KG per hour. It is suitable for residential and industrial and commercial gas in residential areas.

Both the electric control device and the electric heater adopt explosion-proof design, and the explosion-proof grade is Ex DIIBT4.

The process structure of the vaporizer is sturdy and durable, and has anti-corrosion properties.

The electric control box and the vaporizer are installed separately, which is convenient and practical.

The detection pressure of the vaporizer is 3.3MPa (33kg/cm2), and the safety rated pressure is: 1.76MPa (17.6kg/cm2).

The explosion-proof solenoid valve automatically closes when the gas outlet passes through the liquid.

The safety relief valve can automatically discharge the overpressure gas and then automatically close it.

The secondary electronic thermostat can automatically adjust the water temperature of 50-70 degrees, and the air supply is stable.

 

Sitemap |  Privacy Policy | China Good Quality Lab Testing Equipment Supplier. Copyright © 2024-2025 SKYLINE INSTRUMENTS CO.,LTD . All Rights Reserved.