SKYLINE INSTRUMENTS CO.,LTD info@skylineinstruments.com 86-769-23830463
Product Details
Place of Origin: China
Brand Name: SKYLINE
Certification: CE
Model Number: SL-FL51
Payment & Shipping Terms
Minimum Order Quantity: 1 unit
Price: negotiated
Packaging Details: plywood case
Delivery Time: 20 working days
Payment Terms: T/T, L/C, Western Union, MoneyGram
Supply Ability: 1 unit/ month
Standards: |
IEC61034-1997, GA306.1-2007 Etc |
Burning Room Size: |
W3000*D3000*H3000mm (27m3) |
Material: |
Stainless Steel |
Measurement Range: |
0-100% |
Sensor: |
Photocell, Load Resistance≤100Ω |
Standards: |
IEC61034-1997, GA306.1-2007 Etc |
Burning Room Size: |
W3000*D3000*H3000mm (27m3) |
Material: |
Stainless Steel |
Measurement Range: |
0-100% |
Sensor: |
Photocell, Load Resistance≤100Ω |
Burning room size | W3000*D3000*H3000mm (27m3), made of stainless steel |
Standard fire source | 1.00L±0.01L alcohol |
Illuminant nominal power | 100w, nominal voltage:DC12v±0.01V |
Sensor | photocell, load resistance≤100Ω |
Measurement range | 0~100% |
Alcohol dish | bottom: 210mm×110mm;top:240mm×140mm;height:80mm |
Desktop fan | Rotating shaft is 200mm~300mm from found, 500mm±50mm from wall. Fan blades size of 300mm ± 60mm, wind speed:7~15 m3/min |
Min size | 100mm×100mm,height: 2150mm |
What is smoke density?
This test measures the amount of smoke given off by a material that is burning or smoldering. The material is tested when it begins to smolder and again when a flame source is added. The smoke density is between 0 (no smoke generated) and 800. Most finishes and materials require a rating of 450 or less.
3 Metre Cube Smoke Density Test Apparatus.pdf