- Home
-
PCB Fab
Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
- Assembly
- Capabilities
- About Us
- contact
- Quote
PCB Fab
-
Lab Testing Equipment
-
Flammability Testing Equipment
-
Fire Testing Equipment
-
Test Equipment
-
Mattress Testing Machine
-
Environmental Test Chamber
-
Toys Testing Equipment
-
Oil Analysis Testing Equipment
-
Footwear Testing Equipment
-
Furniture Testing Equipment
-
Tensile Strength Testing Machine
-
Textile Testing Equipment
-
Leather Testing Equipment
-
Temperature And Humidity Test Chamber
-
Electronic Testing Equipment
-
Building Materials Flammability Tester
-
Cosmetics Testing Equipment
-
bobRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
WilliamRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
tomRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China
Desktop Turbidity Water Quality Detection Analyzer LED Digital Display
| Display: | LED Digital Display |
|---|---|
| Resolution: | 0.01NTU |
| Accurate Error: | ±2%FS |
| Repeatable Error: | ±2%FS |
| Sampling Volume: | 50ML |
SL-OA69 Copper Content Monitoring Analyzer Intelligent
| Display: | 480X272 Color Touch Screen |
|---|---|
| Measuring Range: | 0—200ug/L |
| Indication Error: | ±2%FS |
| Resolution: | 0. 1 Ug/L |
| Repeatability: | ≤1% |
SL-OA68 UV Vis Spectrophotometer 4nm Spectral Bandwidth
| Optical System: | Single Beam, 1200 Lines/mm Diffraction Grating |
|---|---|
| Spectral Bandwidth: | 4nm |
| Wavelength Range: | 200-1000nm |
| 200-1000nm: | ±0.5nm |
| Wavelength Repeatability: | 0.2nm |
COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Rapid Tester SL-OA67
| Measuring Range: | Chemical Oxygen Demand (COD): 5-10000mg/L Segmented Measurement |
|---|---|
| Ammonia Nitrogen: | ≤3%; Total Phosphorus: ≤3%; Total Nitrogen: ≤±% |
| Total Phosphorus: | 0.02-20mg/L |
| Total Nitrogen: | ≤±5% (FS) |
| Measurement Error: | Chemical Oxygen Demand (COD): 5-200mg/L; Error ≤ 5mg/L 100-10000mg/L; Relative Error≤±5% |
SL-OA66 Infrared Photometric Oil Meter High Precision Analytical
| Wavenumber Scanning Range: | 3400cm-1~2400cm-1 Wavenumber |
|---|---|
| Repeatability: | ±1cm-1 Wavenumber |
| Accuracy: | ±1cm-1 |
| Spectrum Resolution: | 1 Cm-1 |
| Absorbance Linear Range: | 0.0000~1.9999 |
Microcoulomb Sulfur Chloride Analyzer easy to operate
| Bias Voltage Range: | 0 ~ 500mv |
|---|---|
| Measuring Range: | 0.1~10000 Ng/μl |
| Temperature Control Range: | Room Temperature ~ 1000 ℃ |
| Temperature Control Accuracy: | ±1°C |
| Measurement Accuracy: | Sample Concentration (ng/μl) 0.2 RSD(%)35 Sample Concentration (ng/μl) 1.0 RSD (%)10 Sample Concentration (ng/μl) 100 RSD(%)5 Sample Concentration (ng/μl)1000 RSD(%)2 |
Portable Particle Size Counter Easy To Use SL-OA63
| Microscope: | 100 Times |
|---|---|
| Detection Of Particles: | 5μm ~ 150μm |
| Detection Level: | NAS Level 00-12, ISO Level 1-24 |
| Filter Membrane: | 1.2μm, 5μm |
| Accuracy: | ±0.5 Pollution Level |
Oil Gas Separation Corrosive Sulfur Tester Automatic Insulating
| Temperature Control Range: | 35-200°C |
|---|---|
| Temperature Control Accuracy: | ±0.1°C |
| Temperature Control Uniformity: | ±1℃ |
| Timing Range: | 0.0-999.9 Hours |
| Alarm Function: | After The Timing Is Over, An Automatic Alarm Prompts |
Fully Automatic Insulating Oil Gas Separation Tester 1200rpm
| Constant Temperature: | 80℃ |
|---|---|
| Accuracy: | ±0.2 |
| Resolution: | 1S |
| Test Voltage: | 10.00KV |
| Time Measurement: | 5 MIN; 10 MIN; 50MIN; 60MIN; 120MIN |
ASTM D2699 Octane And Cetane Value Tester Portable
| Octane Number Measurement Range: | 40-120 |
|---|---|
| Allowable Measurement Error Of Octane Number Meter: | 0.5 |
| Floating Range Of Octane Number Meter Measurement Results: | ± 0.2 |
| Allowable Measurement Error Of Cetane Number Meter: | ± 1 |
| Floating Range Of Cetane Number Meter Measurement Results: | ± 0.5 |