SKYLINE INSTRUMENTS CO.,LTD info@skylineinstruments.com 86-769-23830463
Product Details
Place of Origin: CHINA
Brand Name: SKYLINE
Certification: Calibration Certificate
Model Number: SL-DBF
Payment & Shipping Terms
Minimum Order Quantity: 1 unit
Price: negoitable
Packaging Details: Plywood case
Delivery Time: 35 working days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1 unit
SKYLINE: |
Fireproof-Coating-Tester |
Voltage And Power: |
220V±10%. 50Hz,300W |
Air Volume Of Blower: |
(1-5) M³/min |
Timer Error: |
≤ 1s/h |
Relative Humidity: |
≤85% |
Gas Source: |
Liquefied Petroleum Gas |
SKYLINE: |
Fireproof-Coating-Tester |
Voltage And Power: |
220V±10%. 50Hz,300W |
Air Volume Of Blower: |
(1-5) M³/min |
Timer Error: |
≤ 1s/h |
Relative Humidity: |
≤85% |
Gas Source: |
Liquefied Petroleum Gas |
Technical parameters
1.PLC+NA view professional software, touch screen control, easy operation
2. Voltage and Power: 220V±10%. 50Hz,300W
3. Working Environment: indoor , no forced ventilation
4. Air Volume of Blower: (1-5) m³/min
5. Armored Thermocouple: Outer diameter ≤3mm, Wire diameter 0.5mm , Accuracy ≥II level,Range 1300℃
6. Timer Error ≤ 1s/h
7. Backfire five-way thermocouple temperature,alarm when it comes to 220℃
8.Environmental Temperature: -5℃-30℃
9. Relative Humidity: ≤85%
10. Gas Source: Liquefied petroleum gas
11. Instrument Dimensions: Test plate bracket 760mm*760mm*1500mm
Control box 800mm*500mm*500mm
12. Specimen Size: 900mm*900mm*5mm +0.2mm Plywood of five layers of first level
13. Time of Automatic Controlling——Temperature Rise and Record
14.Alarm when temperature of time back fire comes 220℃
Design Standards
<Grading and Testing Method of Function of Fireproof Of Facing Fire-retardant Coating——Method of large plate>