- Home
-
PCB Fab
Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
-
Assembly
-
Capabilities
- About Us
- contact
- Quote
Flame Burn Time of 15 seconds Fully Adjustable Flammability Testing Equipment with 600mm Tested Wires Length
| Product Category: | Flammability Testing Equipment |
|---|---|
| Tested Wires Length: | 600mm(24 In) |
| Gas Flow Controls: | Precision |
| Interior Color: | Black |
| Standards Met: | UL94, ISO 6722, IEC 60695-11-3, IEC 60695-11-4, UL94HB, V-0,1,2, 94-5VA,B, 94VTM-0,1,2, 94HBF,94HF-1,2 |
Stainless Steel Flammability Testing Equipment with 45 Degree Sample Clamping Angle and Black Interior Color
| Specimen Support: | Fully Adjustable |
|---|---|
| Product Category: | Flammability Testing Equipment |
| Interior Color: | Black |
| Gas Flow Controls: | Precision |
| Automatic Ignition: | Yes |
50Hz Power Supply Flammability Testing Equipment With Adjustable Gas/ Area Flow Range
| Application: | Applies To Check Thesingle Insulation Wire And Cable Vertical Spreading Test Which Total Section Area Less Than 0.5mm2 |
|---|---|
| Burning Time: | Continuously Setting Between 0.1-999.9S, During The Setting Time Flame Could Continuously Burning The Specimen |
| Temperature Measurement System: | According To GB/T5169.14-2007 And IEC60695-11-03 Standard Requirements, Including Temperature Copper (10g), K Type Thermocouple And Diameter Is 0.5 Mm With Stainless Steel Sheathed, Stopwatch And Thermometer Etc. |
| Standards: | IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1 |
| Gas Flow Range: | 0.1-1L/min(100~1000cm3/min), Can Be Adjusted |
Interior Color Black Cable Flambility Tester with 15 Seconds Flame Burn Time
| Burning Gas Supplied: | No, Customer Should Supply |
|---|---|
| Thermocouple Type: | K (Ni/Cr - Ni/Al) |
| Product Name: | Horizontal-Vertical Flammability Test Chamber UL94, ISO 6722 |
| Product Category: | Flammability Testing Equipment |
| Suitable For: | Conductor Diameter Greater Than 8mm (section Area Is Greater Than 0.5mm2) Or Less Than 8mm (section Area Less Than 0.5mm2) Of Single Wire And Cable Flammability Evaluation. Suitable For Lighting Equipment, Low-voltage Electrical Appliances, Household Appli |
Φ 9.5mm±0.3mm Burner Tube Flammability Testing Equipment for Liquefied Petroleum Gas
| Burning Gas: | High Purity Propane Gas, Liquefied Petroleum Gas |
|---|---|
| Suitable For: | Conductor Diameter Greater Than 8mm (section Area Is Greater Than 0.5mm2) Or Less Than 8mm (section Area Less Than 0.5mm2) Of Single Wire And Cable Flammability Evaluation. Suitable For Lighting Equipment, Low-voltage Electrical Appliances, Household Appli |
| Specimen Support: | Fully Adjustable |
| Burning Gas Supplied: | No, Customer Should Supply |
| Standards Met: | UL94, ISO 6722, IEC 60695-11-3, IEC 60695-11-4, UL94HB, V-0,1,2, 94-5VA,B, 94VTM-0,1,2, 94HBF,94HF-1,2 |
Temperature Measurement System Cabel Flammability Test Chamber For IEC60332-1-3 2004 Standards
| Area Flow Range: | 0.1-1m3/h(1.66~16.6dm3/min), Can Be Adjusted |
|---|---|
| Gas Flow Range: | 0.1-1L/min(100~1000cm3/min), Can Be Adjusted |
| Standards: | IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1 |
| Chamber Size: | W300 * D450 * H1200mm |
| Burner: | 46~78mm For Height Of Blue Luminous Cone, 148~208mm For Total Height Of Flame, Which According To GB/T5169.14-2007, IEC60695-11-2 |
Affordable Electrical Cable Testing Equipment with 600±25mm Specimen Length
| Burning Time: | Continuously Setting Between 0.1-999.9S, During The Setting Time Flame Could Continuously Burning The Specimen |
|---|---|
| Product Category: | Flammability Testing Equipment |
| Specimen Length: | 600±25mm |
| Vertical Burning Chamber: | W300 * D450 * H1200mm |
| Area Flow Range: | 220V±10%, 50Hz |
220V Flammability Testing Equipment For Total Section Area Less Than 0.5mm2
| Control Function: | Switch Can Choose To Be Manual Or Automatically According To The Actual Needed |
|---|---|
| Area Flow Range: | 0.1-1m3/h(1.66~16.6dm3/min), Can Be Adjusted |
| Chamber Size: | W300 * D450 * H1200mm |
| Product Name: | EC60332/EN50265-1 Single Cable Vertical Flaming Test Machine Cable Flammability Assessment Chamber |
| Standards: | IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1 |
600±25mm Cable Flame Test Stopwatch And Thermometer For Accurate Temperature Reading
| Product Name: | EC60332/EN50265-1 Single Cable Vertical Flaming Test Machine Cable Flammability Assessment Chamber |
|---|---|
| Gas Flow Range: | 0.1-1L/min(100~1000cm3/min), Can Be Adjusted |
| Temperature Measurement System: | According To GB/T5169.14-2007 And IEC60695-11-03 Standard Requirements, Including Temperature Copper (10g), K Type Thermocouple And Diameter Is 0.5 Mm With Stainless Steel Sheathed, Stopwatch And Thermometer Etc. |
| Testing Temperature: | This Device Is Located In A Stuffiness Room And The Temperature Keeping The 23±10℃ For Testing |
| Burner: | 46~78mm For Height Of Blue Luminous Cone, 148~208mm For Total Height Of Flame, Which According To GB/T5169.14-2007, IEC60695-11-2 |
ISO 340 Conveyor Belt Vertical Burning Test Chamber
| Materails: | Steel |
|---|---|
| Standards: | ISO340 |
| Bunsen Burner: | The Inner Diameter Is 10.5mm |
| Bunsen Burner Rotation Angle: | 0°~45° Adjustable |
| Thermocouple: | Type K Armor |