- Home
-
PCB Fab
Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
- Assembly
- Capabilities
- About Us
- contact
- Quote
PCB Fab
-
Lab Testing Equipment
-
Flammability Testing Equipment
-
Fire Testing Equipment
-
Test Equipment
-
Mattress Testing Machine
-
Environmental Test Chamber
-
Toys Testing Equipment
-
Oil Analysis Testing Equipment
-
Footwear Testing Equipment
-
Furniture Testing Equipment
-
Tensile Strength Testing Machine
-
Textile Testing Equipment
-
Leather Testing Equipment
-
Temperature And Humidity Test Chamber
-
Electronic Testing Equipment
-
Building Materials Flammability Tester
-
Cosmetics Testing Equipment
-
bobRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
WilliamRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
tomRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China
Keywords
[ vertical flammability chamber ]
match 91 products.IEC60331-11:19999 Over Current Fire Testing Equipment For Wires And Cables Resistance To Fire
| Standards: | IEC60331-11:19999, IEC60331-21:1999, IEC60331-23:1999, IEC60331-25:1999 |
|---|---|
| Laboratory: | 27m3 |
| Gas Flow Range: | 1-10L/min |
| Burning Time: | 0~999.9S/ M/H |
| Highlight: | flammability test chamber,flammability testing labs |
16 CFR1633 Mattress Heat Emission Tester With Two Indicators
| Mattress: | Burning Test Apparatus |
|---|---|
| Standard: | 16CFR 1633 |
| Gas Analyzer: | Servomex |
| Mass Flowmeter: | Range 0-450mg/s, Accuracy ±(0.8%rdg+0.2%F.S.) |
| Calibrated Gas Flow Control: | The Range Is 0-7g/s, The Accuracy Is ±(0.8%rdg+0.2%F.S.) |
Thermal Conductivity System Tester for Measure the Thermal Conductivity of Thermal Insulation Materials
| SKYLINE: | Thermal Conductivity System Tester |
|---|---|
| Specimen Specifications: | 300 × 300 (mm) |
| Thickness: | 10 To 40 (mm) |
| Cold Plate Temperature: | 10 ° C ~ 50 ° C |
| Test Accuracy: | ≤ 3% |
Electric Wire Test Equipment with Automatic Ignition and K Ni/Cr Ni/Al Thermocouple Type
| Suitable For: | Conductor Diameter Greater Than 8mm (section Area Is Greater Than 0.5mm2) Or Less Than 8mm (section Area Less Than 0.5mm2) Of Single Wire And Cable Flammability Evaluation. Suitable For Lighting Equipment, Low-voltage Electrical Appliances, Household Appli |
|---|---|
| Volume Of Chamber: | >0.5m³ |
| Product Category: | Flammability Testing Equipment |
| Thermocouple Type: | K (Ni/Cr - Ni/Al) |
| Automatic Ignition: | Yes |
600±25mm Cable Flame Test Stopwatch And Thermometer For Accurate Temperature Reading
| Product Name: | EC60332/EN50265-1 Single Cable Vertical Flaming Test Machine Cable Flammability Assessment Chamber |
|---|---|
| Gas Flow Range: | 0.1-1L/min(100~1000cm3/min), Can Be Adjusted |
| Temperature Measurement System: | According To GB/T5169.14-2007 And IEC60695-11-03 Standard Requirements, Including Temperature Copper (10g), K Type Thermocouple And Diameter Is 0.5 Mm With Stainless Steel Sheathed, Stopwatch And Thermometer Etc. |
| Testing Temperature: | This Device Is Located In A Stuffiness Room And The Temperature Keeping The 23±10℃ For Testing |
| Burner: | 46~78mm For Height Of Blue Luminous Cone, 148~208mm For Total Height Of Flame, Which According To GB/T5169.14-2007, IEC60695-11-2 |
Interior Color Black Cable Safety Test Equipment with Fully Adjustable Support
| Tested Wires Length: | 600mm(24 In) |
|---|---|
| Thermocouple Type: | K (Ni/Cr - Ni/Al) |
| Flame Burn Time: | 15 Seconds |
| Standards Met: | UL94, ISO 6722, IEC 60695-11-3, IEC 60695-11-4, UL94HB, V-0,1,2, 94-5VA,B, 94VTM-0,1,2, 94HBF,94HF-1,2 |
| Product Category: | Flammability Testing Equipment |
Interior Color Black Cable Flambility Tester with 15 Seconds Flame Burn Time
| Burning Gas Supplied: | No, Customer Should Supply |
|---|---|
| Thermocouple Type: | K (Ni/Cr - Ni/Al) |
| Product Name: | Horizontal-Vertical Flammability Test Chamber UL94, ISO 6722 |
| Product Category: | Flammability Testing Equipment |
| Suitable For: | Conductor Diameter Greater Than 8mm (section Area Is Greater Than 0.5mm2) Or Less Than 8mm (section Area Less Than 0.5mm2) Of Single Wire And Cable Flammability Evaluation. Suitable For Lighting Equipment, Low-voltage Electrical Appliances, Household Appli |
15 Seconds Flame Burn Time Wire Testing Equipment for Commercial Applications
| Construction Material: | Stainless Steel |
|---|---|
| Suitable For: | Conductor Diameter Greater Than 8mm (section Area Is Greater Than 0.5mm2) Or Less Than 8mm (section Area Less Than 0.5mm2) Of Single Wire And Cable Flammability Evaluation. Suitable For Lighting Equipment, Low-voltage Electrical Appliances, Household Appli |
| Standards Met: | UL94, ISO 6722, IEC 60695-11-3, IEC 60695-11-4, UL94HB, V-0,1,2, 94-5VA,B, 94VTM-0,1,2, 94HBF,94HF-1,2 |
| Thermocouple Type: | K (Ni/Cr - Ni/Al) |
| Tested Wires Length: | 600mm(24 In) |
Affordable Electrical Cable Testing Equipment with 600±25mm Specimen Length
| Burning Time: | Continuously Setting Between 0.1-999.9S, During The Setting Time Flame Could Continuously Burning The Specimen |
|---|---|
| Product Category: | Flammability Testing Equipment |
| Specimen Length: | 600±25mm |
| Vertical Burning Chamber: | W300 * D450 * H1200mm |
| Area Flow Range: | 220V±10%, 50Hz |
Cable Fire Resistance Test Equipment UL 2556 / UL 1581
| SKYLINE: | VW-1 Flammability Tester |
|---|---|
| Standards: | UL2556-2013 |
| Burning Time Setting: | 0~999S |
| Air Source: | Methane, Air |
| Test Box Size: | 2m(W)×1.2m(D)×1.8m(H) |