SKYLINE INSTRUMENTS CO.,LTD info@skylineinstruments.com 86-769-23830463

SKYLINE INSTRUMENTS CO.,LTD Company Profile
products
Home > products > Fire Testing Equipment > IEC60331-11:19999 Over Current Fire Testing Equipment For Wires And Cables Resistance To Fire

IEC60331-11:19999 Over Current Fire Testing Equipment For Wires And Cables Resistance To Fire

Product Details

Place of Origin: China

Brand Name: SKYLINE

Certification: CE

Model Number: SL-7606

Payment & Shipping Terms

Minimum Order Quantity: 1 unit

Price: negotiated

Packaging Details: plywood case

Delivery Time: 10 work days

Payment Terms: T/T, L/C, Western Union, MoneyGram

Supply Ability: 1 unit/ month

Get Best Price
Product Details
Highlight:

flammability test chamber

,

flammability testing labs

Standards:
IEC60331-11:19999, IEC60331-21:1999, IEC60331-23:1999, IEC60331-25:1999
Laboratory:
27m3
Gas Flow Range:
1-10L/min
Burning Time:
0~999.9S/ M/H
Standards:
IEC60331-11:19999, IEC60331-21:1999, IEC60331-23:1999, IEC60331-25:1999
Laboratory:
27m3
Gas Flow Range:
1-10L/min
Burning Time:
0~999.9S/ M/H
Product Description
Over-current Flammability Testing Equipment For Wires and Cables Resistance to Fire
 
Application
Applies to check the test integrity of the circuit for wires or cables, use to check the flame retardant properties of insulating refractory characteristics of cable and wires and cables with fireproof layer under overheating, over-current, etc abnormal condition.
 
Standards
According to  IEC60331-11:19999, IEC60331-21:1999, IEC60331-23:1999, IEC60331-25:1999,  and BS6387
 
Technical parameters
 Ribbon burner  500m for length of nozzle, 15mm for width of nozzle. Number of the hole of 1.32mm diameter is totally 470
 Gas flow range  1-10L/min; glass rotor flow meter indicates the current flow, Using propane gas or liquefied petroleum gas (LPG)
 Area flow range  10-100L/min, glass rotor flow meter indicates the current flow
 Position of burner  Burner center horizontal at 70±10mm under the specimen lowest point, nozzle at 45mm distance from the specimen center vertical
 Specimen supported  150mm for inner diameter of metal ring, using 12mm stainless steel materials.NO:5
 Thermocouple  K type thermocouple with stainless steel sheathed, which diameter is 1.5mm and according to GB/T 16839.1
 Temperature calibration  2pcs of thermocouples display data average value between 750+50-10℃required in 10 minutes, and difference value between average value and either of the two thermocouple’s display data cannot over the 40℃
 Test power  Output voltage is AC0~1000V and output current is AC0.01-0.70A, four circuits adjustable independent
 Burning time  0~999.9S/ M/H adjustable
 Laboratory  27m3

 

 

What is a test fire and why is it important?
What Is Fire Testing? Fire testing intends to understand the influence of a direct flame on a material or product. Companies may analyze the effect on wiring or cable, building materials or furnishings.

 

IEC60331-11:19999 Over Current Fire Testing Equipment For Wires And Cables Resistance To Fire 0