- Home
-
PCB Fab
Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
-
Assembly
-
Capabilities
- About Us
- contact
- Quote
PCB Fab
-
Lab Testing Equipment
-
Flammability Testing Equipment
-
Fire Testing Equipment
-
Test Equipment
-
Mattress Testing Machine
-
Environmental Test Chamber
-
Toys Testing Equipment
-
Oil Analysis Testing Equipment
-
Footwear Testing Equipment
-
Furniture Testing Equipment
-
Tensile Strength Testing Machine
-
Textile Testing Equipment
-
Leather Testing Equipment
-
Temperature And Humidity Test Chamber
-
Electronic Testing Equipment
-
Building Materials Flammability Tester
-
Cosmetics Testing Equipment
-
bobRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
WilliamRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
tomRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China
Keywords
[ flame test chamber ]
match 100 products.Cable Electronic Testing Equipment IEC60695 Needle Flame Test Chamber
| SKYLINE: | Needle Flame Test Chamber |
|---|---|
| Nner Hole Diameter: | Inner Hole Diameter Φ 0.5mm ± 0.1mm, Diameter,9mm≤Φ, |
| Burner Angle: | 0,°20°, 45° (adjust Flame Height) |
| Power: | 800VA ,220V, 48-60Hz |
| Chamber: | ≥0.5m3 |
Electronic Product Flame Test Apparatus , IEC 60695 Needle Flame Test Chamber
| Standards: | IEC60695 -11-5、GB/T5169.5-2008、GB4706.1-2005 |
|---|---|
| Nner Hole Diameter: | Nner Hole Diameter Φ 0.5mm ± 0.1mm, Diameter ≤Φ 0.9mm,Length ≥ 35mm |
| Burner Angle: | 0- 45°(any Adjustment) |
| Power: | 800VA ,220V, 48-60Hz |
| Chamber: | ≥0.5m3 |
UL 1685 / UL 2556 Standard Vertical Flame And Smoke Release Test Chamber For Fibre Optic Cables
| UL: | UL Cable Vertical-Tray Flaming Test Room(UL1685) |
|---|---|
| Inner Size: | Height 3353mm, Length 2438mm, Width 2438mm; |
| Propane Flow Meter: | 230 Mm³/s |
| Air Flow Meter: | 1330 Mm³/s |
| Standard Luminous Flux: | 2000lm-3000lm |
Wire Flame Test Chamber For Electric Cables Under Fire Conditions Circuit Integrity
| Wire Flame: | Tests For Electric Cables Under Fire Conditions |
|---|---|
| Material: | Stainless Steel |
| Combustion Chamber: Inner Dimensions: | Combustion Chamber: Inner Dimensions: 3M X 3M X 3M Total 27 Cubic Meters. |
| Flow Meter: | Air Flow Meter: 80L/min |
| Temperature Range: | 0~1000°C Can Be Set Arbitrarily. |
IEC60695 Flammability Testing Chamber For Electronic Product
| Standards: | IEC60695 -11-5、GB/T5169.5-2008、GB4706.1-2005 |
|---|---|
| Nner Hole Diameter: | Nner Hole Diameter Φ 0.5mm ± 0.1mm, Diameter ≤Φ 0.9mm,Length ≥ 35mm |
| Burner Angle: | 0- 45°(any Adjustment) |
| Power: | 800VA ,220V, 48-60Hz |
| Chamber: | ≥0.5m3 |
Fire Testing Equipment / Vertical Flame Test Chamber
| Standards: | IEC60332-1-1:2004, |
|---|---|
| Burning Chamber: | 300x1200x450mm(W*H*D) |
| Specimen Length: | 600±25mm |
| Gas Flow Range: | 0.1-1L/min |
| Highlight: | flammability test chamber,flammability testing labs |
600±25mm Cable Flame Test Stopwatch And Thermometer For Accurate Temperature Reading
| Product Name: | EC60332/EN50265-1 Single Cable Vertical Flaming Test Machine Cable Flammability Assessment Chamber |
|---|---|
| Gas Flow Range: | 0.1-1L/min(100~1000cm3/min), Can Be Adjusted |
| Temperature Measurement System: | According To GB/T5169.14-2007 And IEC60695-11-03 Standard Requirements, Including Temperature Copper (10g), K Type Thermocouple And Diameter Is 0.5 Mm With Stainless Steel Sheathed, Stopwatch And Thermometer Etc. |
| Testing Temperature: | This Device Is Located In A Stuffiness Room And The Temperature Keeping The 23±10℃ For Testing |
| Burner: | 46~78mm For Height Of Blue Luminous Cone, 148~208mm For Total Height Of Flame, Which According To GB/T5169.14-2007, IEC60695-11-2 |
IEC 60332-1-1 1 KW Single Insulated Wire And Cable Vertical Flame Test Equipment
| SKYLINE: | Wire And Cable Vertical Flame Test Equipment |
|---|---|
| Vertical Burning Chamber: | 60x45x156cm |
| Length Of Specimen: | 600±25mm |
| Burner: Inner Diameter: | Φ9.5mm ± 0.5mm |
| Flame Height: | 20mm ± 2mm To 190mm ± 1mm Adjustable |
Horizontal Vertical Flammability Test Chamber UL94, ISO 6722
| Tested Wires Length:600mm(24 In): | Sample Clamping Angle:45 Degree |
|---|---|
| Burning Gas Using High Purity Propane Gas: | Liquefied Petroleum Gas |
| Automatic Ignition: | Flame Burn The Sample Continue 15 Seconds And Be Off Automatically |
| Burning Gas Is Not Supplied With The Tester: | It Should Be Supplied By Customer |
| Meet Standards: | UL94, ISO 6722 |
IEC60695 Laboratory Needle Flame Tester For Insulation Material Fire Testing
| Standards: | IEC60695 -11-5、GB/T5169.5-2008、GB4706.1-2005 |
|---|---|
| Nner Hole Diameter: | Nner Hole Diameter Φ 0.5mm ± 0.1mm, Diameter ≤Φ 0.9mm,Length ≥ 35mm |
| Burner Angle: | 0- 45°(any Adjustment) |
| Power: | 800VA ,220V, 48-60Hz |
| Chamber: | ≥0.5m3 |