Textile Fabric Surface Resistance Tester EN 1149-1/ EN 1149-2/ AATCC 76/ BS 6524

Place of Origin China
Brand Name Skyline
Certification CE, Rosh, Calibration
Model Number SL-F60B
Minimum Order Quantity 1
Packaging Details plywood case
Delivery Time 35 working days
Payment Terms L/C, T/T
Supply Ability 15 sets per month
Product Details
Measuring Voltage: DC100V Built-in Timer: Automatic Reading Lock, Easy To Test
Working Environment: Temperature: 23℃±1℃, Humidity: 25%±5%RH Power Supply Form: AC 220V, 50HZ, Power Consumption 30W
Resistance Measurement Range: 2 × 1014Ω Basic Error: ≤ ± 10%
Highlight:

Textile Fabric Surface Resistance Tester

,

EN 1149-2 Resistance Tester

Product Description

Introduction:

This instrument can be used to measure the anti-static clothing, protective clothing of various fabrics, carpets, films and other insulating materials protective clothing surface resistivity and point-to-point resistance test, the size of the surface resistance can indirectly reflect the test material surface electrostatic leakage time, thus reflecting the test material with static performance.

Applicable standards: GB 12014-2019, GB/T 22042-2008, GB/T12703.4-2010, GB/T 1410, FZ/T64013, BS6524, BS EN1149-1:2006, EN1149-2 AATCC 76 etc.

 

Main technical indicators

1. Adopt high integrated 3 1/2 digit display.

2. Measuring voltage:DC100V

3. Built-in timer: automatic reading lock, easy to test.

4. Working environment temperature: 23℃±1℃, humidity: 25%±5%RH

5. resistance measurement range up to 2 × 1014Ω, is the current point-to-point resistance measurement capability of the stronger digital instrument. It is the best instrument for volume resistivity and surface resistivity measurement of insulation materials, with the highest resolution of 100Ω.

6. Four kinds of (100V, 250V, 500V, 1000V) output voltages are equipped as standard.

Note: Or four (10V, 50V, 100V, 500V) output voltages, the

7. the instrument in a stable working voltage and no signal input between 1 to 8 hours zero point drift less than ± 5%

8. the instrument on the standard resistance measurement of the basic error: ≤ ± 10%

9. power supply form: AC 220V, 50HZ, power consumption 30W

 

Configuration List

1. test host 1 set

2. point-to-point electrode 1set (optional)

Surface resistivity electrode 1set(optional)

3. Electrode contact plate 1 group

4. Insulation pad board 1 piece

5. Electrode distance plate 1 piece

6. Product instruction manual

7. Power cord 1

Digital Display Fabric Surface Resistivity Tester EN 1149-1 / EN 1149-2 AATCC 76 1Digital Display Fabric Surface Resistivity Tester EN 1149-1 / EN 1149-2 AATCC 76 2