Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
-
Assembly
-
Capabilities
- About Us
- contact
- Quote
Automated Cold Cranking Simulator ASTM D5293
| Temperature Range: | External Circulation Alcohol Bath Temperature Control Range Normal Temperature ~ -70 ° C |
|---|---|
| Cold Bath Temperature Control Accuracy: | ±0.1 °C |
| Stator Temperature Control Accuracy: | ±0.05 °C |
| Viscosity Measurement Range: | 1200 ~ 27000 MPa.s |
| Use Environment: | 10 ° C ~ 40 ° C |
ASTM D7097 Thermo Oxidation Engine Oil Simulation Tester Teost Mht
| Test Standard: | ASTM D7097,ASTM D6335 |
|---|---|
| Test Method: | Teost |
| Temperature Range: | Ambient~500ºC |
| Temperature Accuracy: | ±2ºC |
| Test Time: | 24 Hours |
ISO4406 Portable Particle Counter For Hydraulic And Lubricating Oil Analysis
| Light Source: | Semiconductor Laser |
|---|---|
| Sample Viscosity: | ≤350cSt |
| Flow Rate Range: | 20~60mL/min |
| Online Detection Pressure: | 0.1~0.6Mpa (optional Pressure Reduction Device Up To 40 MPa) |
| Sample Temperature: | 0~80℃ |
Brake Fluid Balance Reflux Boiling Point Tester Upper / Lower Structure
| Input Voltage: | AC 220V±10% 50HZ |
|---|---|
| Input Power: | 1.0KW |
| Voltage Regulation Range: | 0~220V |
| Ambient Temperature: | Room Temperature Around 25°C |
| Relative Humidity: | <85%RH |
ASTM D566 Grease Dropping Point Tester Lubricant Melting Point Apparatus ISO217
| Heating Power: | 500W |
|---|---|
| Stirring Motor Power: | 3W |
| Stirring Motor Rotation Speed: | 100r/min |
| Dimensions: | 180×200×360(mm) |
| Weight: | About 6kg |
Ultraviolet Fluorescence UV Sulfur Content Tester ASTM D5453
| Sample Type: | Liquid, Solid And Gas |
|---|---|
| Determination Method: | UV Fluorescence Method |
| Sample Injection Amount Solid Sample: | 1-20mg |
| Liquid Sample: | 5-20μL |
| Gas Sample: | 1-5mL |
Resistant Oil Petroleum Products Chlorine Content Meter SL-OA72
| Oxygen Bomb Pressure Resistance: | ≥20MPa |
|---|---|
| Ignition Voltage: | 12~24V |
| Repeatability: | 0.0006% |
| Reproducibility: | 0.0027% |
| Ambient Temperature: | 5℃~40℃ |
Desktop Turbidity Water Quality Detection Analyzer LED Digital Display
| Display: | LED Digital Display |
|---|---|
| Resolution: | 0.01NTU |
| Accurate Error: | ±2%FS |
| Repeatable Error: | ±2%FS |
| Sampling Volume: | 50ML |
SL-OA69 Copper Content Monitoring Analyzer Intelligent
| Display: | 480X272 Color Touch Screen |
|---|---|
| Measuring Range: | 0—200ug/L |
| Indication Error: | ±2%FS |
| Resolution: | 0. 1 Ug/L |
| Repeatability: | ≤1% |
SL-OA68 UV Vis Spectrophotometer 4nm Spectral Bandwidth
| Optical System: | Single Beam, 1200 Lines/mm Diffraction Grating |
|---|---|
| Spectral Bandwidth: | 4nm |
| Wavelength Range: | 200-1000nm |
| 200-1000nm: | ±0.5nm |
| Wavelength Repeatability: | 0.2nm |