- Home
-
PCB Fab
Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
- Assembly
- Capabilities
- About Us
- contact
- Quote
Building Materials Flammability Tester Critical Radiant Flux Flammability Testing Equipment
| SKYLINE: | Flooring Radiant Panel Test Apparatus |
|---|---|
| Standards: | EN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253 |
| Heat Flux Measurement Range: | (0-15) Kw / M2 |
| Exhaust Speed: | (2.5 ± 0.2) M / S |
| Gas Flow Rate: | (0.026 ± 0.002) L / S |
BS 476-6 Building Materials Flame Spread Testing Equipment With Stainless Steel Support Frame
| SKYLINE: | Building Materials Flame Spread Testing Equipment |
|---|---|
| Electrical: | 230 Volts Nominal 10 Amps |
| Ambient Temperature: | Operating 10°C To 35°C |
| Pressure: | 1 K Pa |
| Control Module: | 400mm (W) X 500mm X (H) X 400mm (D) |
Iso5660-12002 Cone Calorimeter For Testing The Heat Release Rate Of Building Materials
| SKYLINE: | Cone Calorimeter |
|---|---|
| Standard: | ISO5660-1:2002 |
| Maximum Operating Power: | ≥5KW |
| Cone Heater Power: | ≤5KW |
| Heat Output Heat: | 0~120KW/m2 |
Building Material Burning Or Decomposition Smoke Density Testing Machine
| SKYLINE: | Building Material Burning Or Decomposition Smoke Density Testing Machine |
|---|---|
| Gas Source: | Purity ≥ 95% |
| Smoke Density Measurement Range: | 0~100% |
| Smoke Density Measurement Accuracy: | ± 3% |
| Receiving Lens Focal Length: | 60 ~ 65mm |
Building Materials Flammability Tester Toxic Classification Of Fire Effluents Hazard For Materials Squirrel Cage Method
| Standard: | GB/T 20285:2006 |
|---|---|
| Test Host: | 2100mm (W) X 1650mm X (H) X 700mm (D) |
| Weight: | 178KG |
| Electricity Requirements: | 220 V |
| Control Box: | 900mm (W) X 1650mm X (H) X 700mm (D) |
Building Materials Flammability Tester Test Method For Flammability Of Rigid Cellular Plastic
| SKYLINE: | Rigid Foam Vertical Burning Tester |
|---|---|
| Standard: | ASTM D3014 GB 8624:2012, GB/T 8333:2008 |
| Installation Requirements: Electricity Requirements: | 220V, 50HZ |
| Size: | 420 Mm (W) X 350 Mm (D) X 520 Mm (H) |
| Weight: | 15KG |
BS 8414-1 Fire - Proof Test For Outer Wall External Thermal Insulation System
| Standard: | BS 8414-1:202 / GB/T 29416:2012 |
|---|---|
| Wind Speed Sensor: | 0-10M/S, With An Accuracy Of 0.1M/S |
| Electrical Requirements: | 220V, 50HZ, 5A |
| Ignited Time: | Automatically Determined |
| The Test Overtemperature: | Automatically Distinguished |
DIN 4102-1 ISO 11925-2 ( PLC ) Control Building Materials Flammability Ananlyzer
| SKYLINE: | Building Materials Flammability Ananlyzer |
|---|---|
| Standards: | DIN4102-1 DIN 53438 EN ISO 11925-2 |
| Combustion Angle: | 0 ° (vertical), 45 °. |
| Dimension: | 400mm(W)*700mm(D)*600(H) |
| Power: | AC 220V, 50/60Hz, 10A |
Building Material Flame Retardant Testing Machine With Microcomputer Control
| SKYLINE: | Building Material Flame Retardant Testing Machine |
|---|---|
| Gas Flow Rate: | 0 ~ 50L / MIN |
| Air Flow: | 0 ~ 50L / MIN |
| Combustion Gas: | Purity Of 99.5% Methane |
| Highlight: | lab testing equipment,vertical flammability chamber |