- Home
-
PCB Fab
Lab Testing Equipment Flammability Testing Equipment Fire Testing Equipment Test Equipment Mattress Testing Machine Environmental Test Chamber Toys Testing Equipment Oil Analysis Testing Equipment Footwear Testing Equipment Furniture Testing Equipment Tensile Strength Testing Machine Textile Testing Equipment Leather Testing Equipment Temperature And Humidity Test Chamber Electronic Testing Equipment Building Materials Flammability Tester Cosmetics Testing Equipment
-
Assembly
-
Capabilities
- About Us
- contact
- Quote
PCB Fab
-
Lab Testing Equipment
-
Flammability Testing Equipment
-
Fire Testing Equipment
-
Test Equipment
-
Mattress Testing Machine
-
Environmental Test Chamber
-
Toys Testing Equipment
-
Oil Analysis Testing Equipment
-
Footwear Testing Equipment
-
Furniture Testing Equipment
-
Tensile Strength Testing Machine
-
Textile Testing Equipment
-
Leather Testing Equipment
-
Temperature And Humidity Test Chamber
-
Electronic Testing Equipment
-
Building Materials Flammability Tester
-
Cosmetics Testing Equipment
-
bobRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
WilliamRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China -
tomRoom 502.Dongbao Building,No.19 Dongbao Road,Chaoyang,Beijing 201613,China
Door Roller Blind Fire Tester for the Fire Resistance Test of the Building with the Door
Product Details
| SKYLINE: | Door Roller Blind Fire Tester | Furnace Pressure Measurement Range: | 0-100pa |
|---|---|---|---|
| Measurement Accuracy:: | ≤ ± 3pa | Air Flow: | 0-50m3 / Min |
| Gas Tank Capacity: | 50kg × 6 | Gas Flow: | 0-100l / Min |
| Highlight: | horizontal flammability tester,flammability test apparatus |
||
Product Description
Door Roller Blind Fire Tester
Uses
It is suitable for the fire resistance test of the building with the door, the door and the roller blind. The fire resistance limit is determined by experiment.
Technical parameters
1. Working voltage: AC 380v ± 10% 50hz; electricity consumption: 3kw
2. Furnace pressure measurement range: 0-100pa measurement accuracy: ≤ ± 3pa
3. Air flow: 0-50m3 / min measurement accuracy: ≤ ± 0.5 m3 / min
4. Combustion gas source: propane, liquefied gas
5. Gas flow: 0-100l / min measurement accuracy: 2.5
6. Gas tank capacity: 50kg × 6
7. The test piece backfire surface radiant heat measurement range: 0 ~ 10w / cm2;
8. The pressure measurement range of the furnace: indoor pressure ± 150mpa;
9. Test temperature: program temperature 15min room temperature ~ 718 ° C, 30min room temperature ~ 821 ° C, 60min room temperature ~ 925 ° C, 90min room temperature ~ 986 ° C, 120min room temperature ~ 1029 ° C